Specifications:
Manufacturer: SmartLabs Design
Manufacturer Product No.: 2486D, INSTEON KeypadLinc Dimmer
Patent No.: U.S. Patent No. 7,345,998, International patents pending
Warranty: 2 years, limited (Upgradeable to 7 years)
Operation
On-Levels: 32 locally, 1% increments with software
Ramp Rates, (full-ON to full-OFF): 0.125 to 9 seconds if programmed locally,
0.125 seconds to 9 minutes if programmed remotely
LED: Single LED at bottom of unit, indicates supplied power and signals
programming cues
Operation Modes: INSTEON only, X10 only, INSTEON and X10 Combo Mode
Combo Mode Message Order: INSTEON, X10, INSTEON cleanup Multi-Way Circuit
Support: One KeypadLinc Dimmer controls load, Cross-Link any number of
KeypadLinc Dimmers or other INSTEON Controllers
ON/OFF Button Pairs 1 Pair (6 button only)
Setup Memory: Non-volatile EEPROM
INSTEON Features
INSTEON Addresses: 1 hard-coded out of 16,777,216 possible
INSTEON Links: 417 out of 16,777,216 possible
INSTEON Powerline Frequency: 131.65 KHz
INSTEON Minimum Transmit Level: 3.2 Vpp into 5 Ohms
INSTEON Minimum Receive Level: 10 mV
INSTEON Messages Repeated: Yes
Mechanical
Button Type: 6 or 8 mechanical momentary contact type buttons
Button Appearance: Transparent plastic caps, holding preprinted or custom
button labels, with LED backlighting
Wire Nuts: 4 included
Mounting: Mounts in single or multiple-ganged junction box.Controls 200 watts
less load for each immediately adjacent electronic dimmer installed. For
example, 600 watt load capacity becomes 400 watt with another electronic dimmer
installed to the immediate right or left. Use a triple-gang box with a mechanical
switch in the center to avoid de-rating
Operating Conditions: Indoors, 40 to 104°F, up to 85% relative humidity
Dimensions: 4.1" H x 1.8" W x 1.2" D
Weight: 3.6 oz.
Electrical
Supply Voltage: 120 Volts AC +/- 10%, 60 Hertz, single phase
Surge Protection: MOV rated for 150 Volts
Power Wire Leads: 6", 16 AWG, stranded, 600V, 105°C insulation, ends
stripped and tinned, LINE (black), LOAD (red), NEUTRAL (white)
Neutral Wire Required
Maximum Amps 5-amps
Ground Lead: 6", 18 AWG, stranded, bare copper
Load Types: Wired-in incandescent lighting devices
Maximum Load: 600 Watts (uses 12-Amp triac dimmer)
Minimum Load: No minimum load required
Certification: Safety tested for use in USA and Canada (ETL #3059287-001)
X10 Features
X10 Primary Address: 1 optional (comes unassigned)
X10 Scene Addresses: 255 possible
X10 Controllable Addresses 5 X10 address (one per button sent when pressed)
X10 Status Response: Supported
X10 Resume Dim: Supported (by setting Local On-Level to zero)
X10 Powerline Frequency: 120 KHz
X10 Minimum Transmit Level: 3.2 Vpp into 5 Ohms
X10 Minimum Receive Level: 20 mVpp nominal
X10 Messages Repeated: No
Keypad Button Specifications
Manufacturer: SmartLabs Design
Manufacturer Product No.: 2401C8
Dimensions: 1/2" L x 9/16" W x 1/8" D
Button Type: 8 mechanical momentary contact type buttons
Font: Futura Hv BT
Font Size: 6.8
Character Limit: 7 characters per line, upper case recommended
Line Limit: 2
Production Time: 10 to 14 business days